Roof Assembly Fire and Wind Ratings: Verify the Tested System, Not Just the Shingle

Roof fire and wind ratings belong to tested assemblies. How to verify the listing in UL Product iQ, RoofNav, ICC-ES or an NOA, and avoid voiding substitutions.

By ClearTrade Report Editorial Team · Published November 17, 2026 · 11 min read

Four-step framework for verifying roof fire and wind ratings: name the listed assembly, match every layer from deck to covering, match the fastening pattern, and verify the approval in the listing directory.
Credit: ClearTrade Report Editorial Team.

The evidence that verifies a roof approval is a directory listing or evaluation report that names the whole tested assembly, not a rating printed on one product. For fire, ask for the UL Product iQ listing or evaluation report showing the Class A, B or C assembly. For low-slope wind ratings, ask for the FM Approvals RoofNav assembly or UL roof deck construction number. For shingles, check the ASTM D7158 or D3161 class on the label and the evaluation report. Where required, add the Florida Product Approval number or Miami-Dade Notice of Acceptance (NOA). Then compare every layer on the job with that document, because changing the deck, underlayment, insulation, coverboard or fasteners can take the roof outside the rated assembly.

Evidence label: Documentation-based guide. ClearTrade Report Editorial Team checked documents from UL Solutions, FM Approvals, ICC Evaluation Service, the California Building Standards Commission (California Residential Code text), Miami-Dade County, the Florida Department of Business and Professional Regulation, the Asphalt Roofing Manufacturers Association, GAF, CertainTeed and Carlisle SynTec on November 17, 2026. No outside professional review was performed and nothing was tested. Companies named are documentation examples, not recommendations. This guide contains no affiliate links.

Why a product rating is not the roof rating

Roof fire and wind tests are run on built-up samples: a deck, its layers and the fasteners that hold them. The rating belongs to that sample.

FM Approvals says this plainly on its FM Approved roofing page: “An FM Approved roof means you get a tested roof assembly, not simply a collection of products and parts” that may or may not perform as expected. FM’s Approval Standard 4470 (dated April 2022) says “It is therefore necessary to evaluate the entire roof assembly as a single entity.”

UL Solutions’ article “The underlying truth about roofing underlayments” says “A common misconception is that the UL 790 fire classification rating is only based on the roof covering,” and that “the underlayment plays a significant role in achieving the fire rating of the overall roofing system.”

Fire classes A, B and C are assembly results

Code text treats fire class as a property of the roof assembly. Section R902.1 of the 2025 California Residential Code says “Where Class A, B or C roof assemblies are required, they shall be tested in accordance with ASTM E108 or UL 790.” It adds: “Where required, the roof assembly shall be listed and identified as to class by an approved testing agency.” It also lists certain brick, masonry, exposed concrete, metal, tile and slate roof coverings as Class A roof assemblies. This is California’s edition of the residential code, not the national model IRC, so confirm with your building department which code edition applies.

UL’s code-authority newsletter “Class A, B, and C Roof Ratings: Helpful hints for achieving code compliance” defines the classes. Class A coverings are “effective against severe fire test exposures,” Class B against “moderate fire test exposures” and Class C against “light fire test exposures.” It says “Unrated roof assemblies are not suitable for use in any applications requiring a Class A, B or C rating, except when specified in a code,” and that UL’s Guide Information for Roofing Systems “describes specific details for permissible combustible or noncombustible deck constructions.”

Carlisle SynTec’s article on UL fire classifications names the three tests in UL 790 (ASTM E108): “the Spread of Flame Test, Intermittent Flame Test, and Burning Brand Test.” It adds that “the roof components play a significant role in achieving the fire rating of the overall roofing system.”

Manufacturer pages sometimes say this directly. GAF’s Deck-Armor product page says the underlayment “Achieves ANSI/UL 790 Class A roofing fire rating as a component of UL Classified roofing assemblies,” with a footnote: “Refer to UL Product iQ for specific assemblies.”

Wind ratings for shingles and low-slope assemblies

Asphalt shingles. The Asphalt Roofing Manufacturers Association’s summary of shingle standards describes two wind tests. For ASTM D7158, the uplift method, “The laboratory measured values can be directly compared to code prescribed three-second gust design wind speeds,” and “Class H represents the highest (best) wind resistance level.” For ASTM D3161, the fan-induced method, “the fan-induced test is conducted for two hours” and “Class F is the highest (best) rating.”

GAF’s technical bulletin R-138, Wind Resistance of Asphalt Shingles, says the 2018 IBC and IRC require ASTM D7158 testing, with the class set by IBC Table 1504.1.1 or IRC Table R905.2.4.1 for the design wind speed, and an ASTM D3161 exception for shingles outside D7158’s scope. It quotes the code: “Asphalt shingle packaging shall bear a label to indicate compliance with ASTM D7158.”

Installation still matters. CertainTeed’s ICC-ES evaluation report ESR-3537, which covers Landmark Pro and other CertainTeed asphalt shingles, says the shingles “have been tested in accordance with ASTM D7158 and are classified as Class H.” The same report sets a minimum slope of 2:12, requires fasteners to “penetrate into the sheathing 3/4 inch (19.1 mm),” and for high wind areas (for example, an ultimate design wind speed of 140 mph or more under the 2015, 2018 or 2021 IRC) says “Shingles must be fastened with four or five No. 12 gage roofing nails.” It adds that where the installation instructions conflict with the report, “this report governs.”

Low-slope assemblies. FM Approvals rates whole assemblies. Standard 4470 sets the range from “Class 1-60” to “Class 1-990” and says “Ratings between 1-60 and 1-990 are available in increments of 15.” GAF’s building science article “IBC and FM: What’s the difference when it comes to wind design?” explains that the second number in a “1-60” or “1-75” listing “represents the wind-uplift capacity (in pounds per square foot) of the roof system.” It also notes that “Compliance with the local building code is a legal requirement; FM is elective.”

UL uses a different scale. UL’s article “An uplifting experience” describes UL 580, “the Standard for Tests for Uplift Resistance of Roof Assemblies.” Its table shows Classes 15, 30, 60 and 90, and it notes that IBC Section 1504.3 calls for certain membrane roof systems to be tested to UL 580, UL 1897 or FM 4474. A UL Class 90 and an FM 1-90 come from different standards and are not interchangeable.

Approval documentWhat it ratesWhere to verify itWhat to match on the job
UL 790 / ASTM E108 fire classificationClass A, B or C for a tested roof assemblyUL Product iQ, or an evaluation report that cites the classificationCovering, underlayment, deck type and thickness, slope
ASTM D7158 or D3161 shingle wind classShingle wind resistance class (for example Class H or Class F)Package label and the ICC-ES or other evaluation reportNail count and penetration, deck, underlayment, slope as the report states
FM Approvals 1-60 to 1-990 ratingWind uplift and fire performance of a low-slope roof assemblyFM Approvals RoofNavEvery layer: deck, vapor retarder, insulation, coverboard, membrane, fasteners, plates and pattern
UL 580 or UL 1897 Class 15 to 90Uplift resistance of a roof deck constructionUL Product iQ, category TGKX (Roof Deck Constructions)Construction number details, including deck, fasteners and components
Florida Product Approval or Miami-Dade NOACompliance with the Florida Building Code for the listed scopeFlorida Building Code Online search, Miami-Dade Product Approval SearchDeck type, system type, design pressure, limitations, expiration date

How to verify an approval in a directory

UL Product iQ. UL calls Product iQ “our online certifications directory” and says it “is free to use, but requires a simple one-time registration.” UL’s wind article says roof deck constructions are found there under category TGKX (Roof Deck Constructions). Open the specific assembly or construction number and read the full component list. UL adds that certified underlayments “are clearly identified by a UL Certification Mark on the roll, package or container.”

FM Approvals RoofNav. FM says “FM Approved roofing products and assemblies are listed in RoofNav.” Its RoofNav announcement says it “provides unlimited access to FM Approved roof assemblies and products.” The tool offers “a Contractor Package for printing assemblies with the saved components at each layer.” Ask for that printout and check it against delivery tickets.

ICC-ES evaluation reports. ESR-3537 says the shingles “are Class A roof coverings when installed as described in this report,” then names the deck (for example “minimum 3/8-inch-thick (9.5 mm), exterior-grade plywood”) and the allowed underlayments. The copy checked says “Reissued June 2025” and “Subject to renewal June 2026,” so get the current version from ICC-ES.

Florida Product Approval and Miami-Dade NOA. The Florida Department of Business and Professional Regulation runs a product approval search where “You can search for products by FL number or by any search criteria.” Miami-Dade’s Product Control page says new approvals are “Valid for five years.” Read the whole NOA. For example, NOA No. 26-0331.06 for a liquid-applied waterproofing system is limited to “Concrete Decks, Non-Insulated,” lists maximum design pressures by system type, and states “Fire classification is not part of this acceptance.”

Substitutions that can void the listed assembly

FM Standard 4470 is direct: “Certification requirements prohibit substitution of components in the roof assembly” without “prior authorization from the certification agency.” UL’s wind article says the specifications for “the assembly, materials and components” “should be carefully evaluated at the job site to verify” that the construction matches the UL design. These are the changes to watch for:

  • Deck. Listings name deck type and often minimum thickness, as ESR-3537 and the NOA above do. If deck boards are replaced during a tear-off, confirm the new material and thickness fit the listing. Our guide to Roof Deck Replacement: Document the Condition, Quantity and Unit Price covers how to record that work.
  • Underlayment. UL warns that “some noncertified roofing underlayments are often used that have not been adequately evaluated.” Swapping an underlayment named in a fire-rated assembly for a different one can change the result.
  • Insulation and coverboard. In a low-slope assembly these are listed layers. A different board may need a different assembly.
  • Fasteners and pattern. Wind ratings depend on fastener type, plates, spacing and attachment method.
  • Slope and edges. ESR-3537 sets a minimum slope. UL notes that some aspects of a roof deck assembly, including construction details along roof edges and around openings such as skylights and chimneys, are not evaluated using UL 580, so perimeter details need their own documentation.

If a substitution is proposed, ask for written proof that the new combination is itself listed or authorized before it is installed.

Documents to ask a roofer or specifier for

Ask for these before signing and again at closeout:

  • The fire classification evidence: UL Product iQ listing or evaluation report naming the Class and the full assembly.
  • For shingles, the ASTM D7158 or D3161 class on the package label, plus the evaluation report with its fastening and deck conditions.
  • For low-slope roofs, the RoofNav assembly printout or UL construction number, with the wind rating and every layer listed.
  • Florida Product Approval FL number or Miami-Dade NOA where your jurisdiction requires it, with the expiration date.
  • Delivery tickets showing the installed products match the listing.
  • The insurer’s written roof requirement, if a rating is a policy condition.
  • The warranty terms. GAF’s Lifetime Roofing System page says “Lifetime ltd. warranty on accessories requires the use of at least three qualifying GAF accessories,” and points to gaf.com/LRS for eligible products. Warranty rules and listing rules are separate, so check both.

Know the limits of this guide

This guide reads published documents. It does not judge whether any roof complies, and nothing was tested. The code text, ICC-ES report, NOA and manufacturer pages are examples, and listings change, expire or get revised. Only the current directory listing, read in full, shows what is approved today. A design professional or the building official decides required wind pressures and fire classes for a specific building.

Primary references checked November 17, 2026: UL Solutions, The underlying truth about roofing underlayments; UL, The Code Authority newsletter, Class A, B, and C Roof Ratings: Helpful hints for achieving code compliance; UL Code Authorities, An uplifting experience (certifying roof deck constructions for wind resistance); FM Approvals, FM Approved Roofing; FM Approvals, New RoofNav; FM Approvals, Examination Standard Class Number 4470 (April 2022); California Building Standards Commission, 2025 California Residential Code Section R902.1 (as published by GoCodeBook); ICC Evaluation Service, ESR-3537 (CertainTeed asphalt shingles, including Landmark Pro); Asphalt Roofing Manufacturers Association, Asphalt Shingle Product and Test Standards; GAF, Technical Bulletin R-138 Wind Resistance of Asphalt Shingles; GAF, IBC and FM: What’s the difference when it comes to wind design?; GAF, Deck-Armor Premium Breathable Roof Deck Protection product page; GAF, Lifetime Roofing System warranty page; Carlisle SynTec, UL Fire Classifications for Roofs; Miami-Dade County, Product Control page and NOA No. 26-0331.06; Florida Department of Business and Professional Regulation, Florida Building Code Online product approval search.

Frequently asked questions

Is a Class A shingle the same as a Class A roof?

Not necessarily. The 2025 California Residential Code requires Class A, B or C roof assemblies to be tested to ASTM E108 or UL 790, and UL says the underlayment plays a significant role in the rating. Check the listing or evaluation report for the full assembly, including the deck and underlayment.

Where do I look up an FM Approved roof assembly?

FM Approvals lists approved roofing products and assemblies in RoofNav. Ask the roofer for the RoofNav assembly printout, which lists the components at each layer, and compare it with the products delivered to the job.

Can my roofer substitute a different insulation board or underlayment?

Only if the new combination is itself listed or approved in writing. FM Approval Standard 4470 says certification requirements prohibit substitution of components without prior authorization from the certification agency.

Does a Miami-Dade NOA cover fire rating too?

Not always. Read the limitations section. The Miami-Dade NOA checked for this guide states that fire classification is not part of that acceptance, so the fire class has to be confirmed in a separate listing.

Disclaimer: This guide is general information based on manufacturer, standards and government documents, not professional roofing, engineering or code advice for a specific building or product. Confirm required ratings with your building department, design professional and insurer. Listings and codes may change. AI tools assisted with drafting. ClearTrade Report Editorial Team checked the cited sources and edited this guide.

Need a qualified professional?

Trusted Pros uses visible license-verification states and never ranks paid listings above unpaid listings.

Explore Trusted Pros