Match the listing to the job. For an individual shower or tub-shower, the code texts checked here call for a pressure balance, thermostatic or combination valve at the point of use, listed to ASSE 1016/ASME A112.1016/CSA B125.16 (or ASME A112.18.1/CSA B125.1). For sinks, lavatories, bidets and tub fillers, an ASSE 1070 device limits the hot water sent to that fitting. An ASSE 1017 valve belongs at or near the water heater and sets system temperature. ASSE International says it does not give adequate scald protection used alone. Gang showers use a different listing, ASSE 1069.
Evidence label: Documentation-based guide. ClearTrade Report Editorial Team checked documents from ASSE International, CSA Group, the International Code Council, the California Building Standards Commission (California Plumbing Code text), the U.S. Consumer Product Safety Commission, Watts, Symmons and Moen on November 18, 2026. No outside professional review was performed and nothing was tested. Companies named are documentation examples, not recommendations. This guide contains no affiliate links.
Why the standard number matters
The ASSE number on a mixing valve tells you where it is meant to go and what job it was tested to do.
The U.S. Consumer Product Safety Commission’s Avoiding Tap Water Scalds sheet says “The majority of injuries and deaths involving tap water scalds are to the elderly and children under the age of five.”
ASSE International’s white paper Guidelines for Temperature Control Devices in Domestic Hot Water Systems, written by its Scald Awareness Task Group, explains how the standards divide the work.
ASSE 1016: the valve at the shower
CSA Group’s store listing for ASSE 1016/ASME A112.1016/CSA B125.16 gives the full title: “Performance requirements for automatic compensating valves for individual showers and tub/shower combinations.” Its scope says the standard applies to valves “intended to be installed at the point of use,” “where the user has access to flow or final temperature controls” and “where no further mixing occurs downstream of the device.”
ASSE International says three types of shower valve meet the standard: pressure balancing, thermostatic, and combination pressure balancing and thermostatic. It says “These devices provide both scald and thermal shock protection.” It also says “The temperature limit stop must be set at the time of installation, and may need to be periodically adjusted for variations in water temperatures.”
Code text puts this valve at the shower. Section 412.3 of the 2021 International Plumbing Code, as printed in the ICC’s Significant Changes to the IPC 2021 Edition, says these valves “shall be installed at the point of use.” It requires a means to limit “the maximum setting of the valve to 120°F (49°C),” and it says “In-line thermostatic valves shall not be utilized for compliance with this section.” Section 408.4 of the 2025 California Plumbing Code also says the valves “shall be installed at the point of use,” and Section 408.4.2 says “The maximum water temperature discharging from an individual showerhead shall be limited to 120°F (49°C)” by one of the methods it lists.
Moen’s Chateau Posi-Temp shower valve specification describes a “Single handle, pressure balancing, four port, cycle valve” with an “Adjustable temperature limit stop to control maximum hot water temperature,” and lists ASSE 1016 among its standards.
ASSE 1070: sinks, lavatories, bidets and tubs
CSA Group’s listing for ASSE 1070-2020/ASME A112.1070-2020/CSA B125.70:20 is titled “Performance requirements for water temperature limiting devices.” Its scope covers devices “intended to limit the hot or tempered water temperature” “supplied to fittings for fixtures such as sinks, bidets, lavatories, and bathtubs to reduce the risk of scalding.” The same scope says “These devices are not designed to address thermal shock.”
ASSE International says an ASSE 1070 device “Controls and limits outlet water temperature to fittings such as sinks, lavatories, bidets or bathtubs.” It says “The user control allows the outlet temperature to be adjusted up to a maximum temperature of 120° F (49° C),” and “These devices provide scald protection ONLY, and DO NOT provide thermal shock protection.” Unlike ASSE 1016, “Further mixing downstream is allowed.”
The 2025 California Plumbing Code uses ASSE 1070 for fixtures other than showers. Section 407.3 says “Hot water delivered from public-use lavatories shall be limited to a maximum temperature of 120°F (49°C),” using a limiting device conforming to ASSE 1070/ASME A112.1070/CSA B125.70 or a water heater conforming to ASSE 1084. Section 409.4 sets the same limit for bathtub fillers, using a limiting device conforming to ASSE 1070/ASME A112.1070/CSA B125.70 or CSA B125.3, or a water heater conforming to ASSE 1084.
ASSE 1017: the valve at the water heater
ASSE 1017 valves control a hot water distribution system. ASSE International says: “When used, these devices shall be installed at or near the outlet of the hot water source ONLY.” It adds “These valves are NOT intended for point of use applications” and “These devices used alone do not provide thermal shock protection or adequate scald protection.”
Watts’ ASSE standards comparison chart, which compares older editions of the standards, lists the ASSE 1017 application as “Hot water source/boiler” and its category as “Tempered water distribution.” It lists ASSE 1070 as “Point-of-use.”
A product page can be accurate and still not tell you this. Watts’ LF1170 hot water temperature control valve page says the valves “are specifically designed for mixing hot and cold water on hot water supply systems” and meet “the requirements of ASSE 1017 across the rated flow range.”
The paper gives an example: a plumber wants to protect a child’s bath with a device at the water heater. Its answers include an ASSE 1016 tub/shower valve “with the limit stop set to 110° F” or an ASSE 1070 device on the tub’s hot supply. It warns: “Installing a device listed to ASSE 1017 at the water heater will not provide adequate scald protection.”
If you are also documenting the water heater’s closed system, see our guide to Water Heater Expansion Tanks: What Closed-System Documentation Should Show.
ASSE 1069: gang showers
ASSE 1069 covers automatic temperature control mixing valves. ASSE International says they are “Intended to be installed where the end user does NOT have access to the temperature adjustment means,” are “Typically installed for gang (multiple) showers and sitz baths,” and are “NOT intended for individual showers or tub/showers.”
The code texts match. Section 408.4.1 of the 2025 California Plumbing Code says that where gang showers share one temperature-controlled supply pipe, “it shall be controlled by a mixing valve that complies with ASSE 1069.” The 2021 IPC Section 412.4 calls for an “approved automatic temperature control mixing valve that conforms to ASSE 1069 or CSA B125.3.”
| Standard | Where it installs | What it controls | What it does not do |
|---|---|---|---|
| ASSE 1016 / ASME A112.1016 / CSA B125.16 | At the point of use: an individual shower or tub-shower | Water temperature to the shower outlets and tub spout of a tub-shower | No further mixing downstream. Limit stop must be set at installation. |
| ASSE 1070 / ASME A112.1070 / CSA B125.70 | On the hot or tempered supply to a fitting: sinks, lavatories, bidets, bathtubs | Limits the outlet temperature, adjustable up to a 120°F (49°C) maximum per ASSE International | Does not address thermal shock. |
| ASSE 1017 | At or near the outlet of the water heater or other hot water source only | Temperature of the hot water distribution system | Not intended for point of use. Used alone, does not give adequate scald protection. |
| ASSE 1069 | Gang showers and sitz baths, where the user cannot adjust temperature | Scald and thermal shock protection for a shared supply | Not intended for individual showers or tub-showers. |
How to check a spec sheet or a dual-listed valve
Some valves carry more than one listing. Symmons says on its MaxLine Thermostatic Mixing Valve literature that “the MaxLine is dual-certified to ASSE 1070/1017 standards” and that it “can be installed at point of use to limit the temperature of the water to hot side of the fixture.” What matters is where it is installed.
ASSE International says a device listed to multiple standards “when installed to regulate the building’s distribution system temperature should not be considered an ASSE 1069 or ASSE 1070 safety device.” Valves at a water heater “serve as ASSE 1017 point of source applications ONLY,” and “Further point of use temperature control devices must be installed as required.”
When you review a submittal, quote or invoice, check these items:
- The ASSE number. Find it on the spec sheet, not just a phrase like “mixing valve.”
- The shower valve. For each individual shower or tub-shower, look for a valve listed to ASSE 1016 (or the alternative standard your code names) and a note that the limit stop was set.
- Sinks and tubs. Where your code limits temperature at lavatories or tub fillers, look for an ASSE 1070 device or another means the code allows.
- Flow rate. The 2021 IPC says “Shower control valves shall be rated for the flow rate of the installed shower head.”
Know the limits of this guide
This guide reads published documents. It does not judge whether any installation complies, and nothing was tested. It relies on CSA Group’s public scope text and ASSE International’s white paper, not the full paid standards. Codes differ by edition and state. The IPC text here is the 2021 edition, and the California code may not apply where you are. This guide does not cover Legionella control or how hot to set a water heater. Your local code official decides what is required on a given job.
Primary references checked November 18, 2026: ASSE International Scald Awareness Task Group, Guidelines for Temperature Control Devices in Domestic Hot Water Systems (as hosted by IAPMO); CSA Group store listing, ASSE 1016/ASME A112.1016/CSA B125.16; CSA Group store listing, ASSE 1070-2020/ASME A112.1070-2020/CSA B125.70:20; International Code Council, Significant Changes to the IPC 2021 Edition, Sections 412.3 and 412.4; California Building Standards Commission, 2025 California Plumbing Code Sections 407.3, 408.4 and 409.4 (as published by GoCodeBook); U.S. Consumer Product Safety Commission, Avoiding Tap Water Scalds; Watts, ASSE standards comparison chart; Watts, LF1170 Hot Water Temperature Control Valves product page; Symmons, MaxLine Thermostatic Mixing Valve literature; Moen, Chateau Posi-Temp shower valve specification.
Frequently asked questions
Does a mixing valve at my water heater protect my shower from scalding?
Not by itself. ASSE International says a device listed to ASSE 1017 at the water heater will not provide adequate scald protection. Codes checked for this guide require an individual shower or tub-shower valve, such as one listed to ASSE 1016, installed at the point of use.
Which listed valve type limits hot water at a bathroom sink?
ASSE 1070 covers water temperature limiting devices that limit hot or tempered water supplied to fittings for sinks, bidets, lavatories and bathtubs. The 2025 California Plumbing Code accepts an ASSE 1070 device, or an ASSE 1084 water heater, to limit public-use lavatories to 120°F (49°C).
Can one valve be listed to both ASSE 1017 and ASSE 1070?
Yes. Symmons says its MaxLine valve is dual-certified to ASSE 1070 and 1017. But ASSE International says a multiple-listed valve installed at a water heater serves as an ASSE 1017 device only.
What is an ASSE 1069 valve used for?
ASSE International says ASSE 1069 valves are typically installed for gang showers and sitz baths, where the user cannot reach the temperature adjustment. They are not intended for individual showers or tub-showers.
Disclaimer: This guide is general information based on standards, code, government and manufacturer documents, not professional plumbing or code advice for a specific building or product. Confirm requirements with your local code official and a licensed plumber. Standards and codes may change. AI tools assisted with drafting. ClearTrade Report Editorial Team checked the cited sources and edited this guide.