The most useful evidence for comparing portable dehumidifiers is the capacity in pints per day and the integrated energy factor (IEF) measured under the U.S. Department of Energy (DOE) test, along with the test conditions behind each number. DOE tests portable units at 65 °F and 60% relative humidity. Many older and restoration ratings use 80 °F and 60%, and saturation ratings use even wetter air. DOE says the cooler test results in a lower measured capacity, so a 50-pint label can mean very different things. Before you compare, find the stated test condition for each figure, then compare only like with like. Finally, read the manual for how the water leaves the unit (bucket, gravity hose or internal pump) and check the model against federal recall notices.
Evidence label: Documentation-based guide. ClearTrade Report Editorial Team checked documents from the U.S. Department of Energy (Electronic Code of Federal Regulations and Federal Register rules), ENERGY STAR, the U.S. Consumer Product Safety Commission, LG, Midea, Frigidaire, Legend Brands (Dri-Eaz) and Abatement Technologies on November 16, 2026. No outside professional review was performed and nothing was tested. Companies named are documentation examples, not recommendations. This guide contains no affiliate links.
What the federal test measures
The federal test for dehumidifiers is 10 CFR 430 Appendix X1. Its Table 1 sets the standard test conditions. For portable dehumidifiers the room air is held at 65 °F ± 2.0 dry-bulb, 56.6 °F ± 1.0 wet-bulb and 60% ± 2 relative humidity. For whole-home dehumidifiers it is 73 °F ± 2.0 dry-bulb, 63.6 °F ± 1.0 wet-bulb and 60% ± 2 relative humidity. The appendix says “Definitions for terms, modes, calculations, etc. are in accordance with AHAM DH-1-2022,” the industry standard from the Association of Home Appliance Manufacturers.
Two numbers come out of the test. Product capacity is reported “in pints/day.” The second number is efficiency. The appendix tells the lab to “Calculate the integrated energy factor, IEF, in L/kWh, rounded to two decimal places.” ENERGY STAR explains on its dehumidifier buying page that IEF is measured “in liters of water removed per kilowatt-hour (kWh) of energy consumed or L/kWh,” and that “In general, a higher integrated energy factor means a more efficient dehumidifier.”
The test also fixes how the water is handled. If the unit can drain condensate away from the cabinet, the lab must “collect the condensate in a substantially closed vessel” on a scale. If it cannot, the lab must “disable any automatic shutoff of dehumidification mode operation” so a full bucket does not stop the test. The appendix adds: “Do not use any internal pump to drain the condensate into a substantially closed vessel” unless the pump runs by default in dehumidification mode.
Why pint ratings dropped in 2019
Before the current appendix, portable units were rated at warmer conditions. In its July 2015 test procedure final rule, DOE describes the earlier condition as “those in ANSI/AHAM DH-1-2008, 80 °F dry-bulb temperature and 69.6 °F wet-bulb temperature.” DOE concluded that “the 65 °F condition is most representative of consumer usage of the product.” It also said cooler air yields less condensate “than at the current 80 °F, which will result in a lower measured capacity.”
The new test came with new efficiency standards. DOE’s June 2016 standards final rule says compliance with the amended standards “is required on and after June 13, 2019.” In that rule, DOE summarized a comment from AHAM that the lower test temperatures in Appendix X1 would “decrease the measured capacity by about 35 percent, on average.”
ENERGY STAR’s dehumidifier testing and capacity page puts it plainly: “The new test procedure specifies that portable dehumidifiers are tested at 65°F, rather than 80°F.” As a result, “a dehumidifier tested to the new procedure will likely report a smaller capacity.” The page gives an approximate conversion table. It maps an old 30-pint rating to about 20 pints, an old 50-pint rating to about 30 pints and an old 70-pint rating to about 40 to 45 pints.
The industry standard moved too. DOE’s July 2023 test procedure final rule says AHAM DH-1-2017 “lowered the standard dry-bulb temperature condition for dehumidifiers from 80 °F (as in ANSI/AHAM DH-1-2008)” “to 65 °F (with the required wet-bulb temperature changing accordingly to maintain the same relative humidity).” So an “AHAM” figure with no temperature could reflect either condition.
Federal minimums and ENERGY STAR criteria
The June 2016 rule sets minimum IEF levels for portable dehumidifiers by capacity band, measured in pints per day under Appendix X1. Units of 25.00 pints per day or less must reach 1.30 L/kWh. Units of 25.01 to 50.00 pints per day must reach 1.60 L/kWh. Units of 50.01 pints per day or more must reach 2.80 L/kWh. Whole-home units are grouped by case volume instead, with minimums of 1.77 L/kWh for 8.0 cubic feet or less and 2.41 L/kWh for more than 8.0 cubic feet.
ENERGY STAR sets a higher bar. Its key product criteria page says qualified models meet the “Version 6.0 ENERGY STAR Program Requirements” for dehumidifiers “that are effective as of October 1, 2025.” The listed portable minimums are 1.70 L/kWh for 25.00 pints per day or less, 2.01 L/kWh for 25.01 to 50 pints per day, and 3.30 L/kWh for the top capacity band. Whole-home minimums are 2.22 L/kWh for 8.0 cubic feet or less and 3.81 L/kWh above that. ENERGY STAR’s buying page says certified dehumidifiers “are 20% more efficient than non-certified models.”
If you are still deciding whether a portable unit is the right tool at all, our guide to whole-house dehumidifiers versus ventilation covers how to find the moisture source and when a permanent system fits.
| Rating basis | Air condition stated | Where it appears | Example from the documents checked |
|---|---|---|---|
| DOE Appendix X1, portable | 65 °F dry-bulb, 60% RH | Federal capacity and IEF ratings, ENERGY STAR | Midea MAD50PS1QGRC (Canada) sheet: 49.58 pints/day and IEF 1.95 at 18.3/13.7 °C (same temperatures as Appendix X1; the sheet does not name the test) |
| Older DOE Appendix X and AHAM DH-1-2008 | 80 °F dry-bulb, 69.6 °F wet-bulb (60% RH) | Ratings before June 13, 2019, legacy model names | LG UD501KOJ5 sheet: 50 pints/day, footnoted to the 80 °F test |
| Manufacturer “AHAM” for restoration units | As stated on the sheet, for example 80 °F, 60% RH | Restoration and commercial spec sheets | Dri-Eaz LGR 6500XLi: 125 pints at AHAM (80 °F/60% RH) |
| Manufacturer “saturation” | As stated, for example 90 °F, 90% RH | Restoration and commercial spec sheets | Dri-Eaz LGR 6500XLi: 245 pints at saturation; AQUATRAP® AT250RS: up to 266 pints at saturation |
Reading a portable unit’s spec sheet
Start with the capacity line and look for an asterisk. LG’s specification sheet for the UD501KOJ5 lists “Dehumidification (pts/day) 50.0” and “IEF 1.80.” Its footnote, headed “Pint Removal Performace Operating Conditions” (spelling as printed), explains that “Under the DOE test standards before June, 13th in 2019 (DOE Test Procedure 10 CFR Part 430, subpart B, appendix X)” “the pint removal performance was at 80°F.” It adds that after that date the DOE test standard “changed to 65° F.” The sheet gives no separate pint figure at 65 °F. LG’s product page for the same model shows “Dehumidification (Pts/Day) 50*” and marks the product “DISCONTINUED.”
Midea shows a different pattern. Its Canadian specification sheet for model MAD50PS1QGRC carries a “50 Pints/Day” header but lists “Moisture removal(18.3/13.7 ℃) Pints/Day 49.58” and “Rated IEF(18.3/13.7 ℃) L/kWh 1.95.” Those Celsius values are the metric equivalents of the 65 °F dry-bulb and 56.6 °F wet-bulb conditions in Appendix X1’s Table 1. Midea’s U.S. product page for the MAD50PS1QWT lists “Capacity 50 Pints/day” but does not state the test basis on that page.
The lesson from both examples: the big number on the box may follow one test while the IEF and the fine print follow another. When a page does not state the condition, ask the manufacturer which test produced the pint figure before comparing it with another model.
Check the low-temperature limit for a cool basement or crawlspace. LG’s sheet lists “Low Temperature Operation (˚F) 41.” A Frigidaire use and care manual says “The unit is designed to operate between 41 °F (5 °C), and 89 °F (32 °C).”
Restoration units: AHAM and saturation figures
Water damage restoration equipment is usually sold with two water removal numbers. Legend Brands’ specifications page for the Dri-Eaz LGR 6500XLi lists water removal at “AHAM (80°F/60% RH)” of “125 pts.” and at “saturation (90°F/90% RH)” of “245 pts.” The same line also prints a Celsius condition that does not match the Fahrenheit one, so confirm the saturation condition with the manufacturer if it matters to your comparison. The page lists a drain hose length of “40 ft.”
Abatement Technologies’ AQUATRAP® AT250RS LGR Dehumidifier page claims “147 pints/day water removal @ AHAM” and “up to 266 Pints Per Day @ saturation.” That page does not state the temperature and humidity behind either figure.
Neither figure is a DOE Appendix X1 portable rating at 65 °F. The AHAM figure on the Dri-Eaz page is at 80 °F, the same temperature the federal test used before 2019. A saturation figure describes much wetter air. Use these numbers to compare restoration units that state the same conditions. Do not set them beside a household unit’s DOE rating.
Bucket, gravity drain or internal pump
Drainage does not change the federal rating, but it decides whether a unit can run unattended. There are three common setups.
Bucket. The Frigidaire use and care manual says “When the bucket is full, the unit will shut down and the BUCKET FULL indicator will illuminate.” Once the bucket fills, the unit stops removing water until someone empties it.
Gravity drain hose. The same Frigidaire manual says “For continuous drainage operation, you will need a garden hose and a drain nearby to discharge the water into.” It warns: “Make sure there are no kinks or elevations in the hose.” ENERGY STAR advises: “Keep drain hoses away from electrical cords and connections.”
Internal pump. A pump can push water up to a sink or window. Frigidaire’s manual says “The maximum distance and the rise may be 5m from the unit. Exceeding this distance may damage the unit or cause leaks.” It also says “The unit will not pump untill it reaches the full bucket point” (spelling as printed). Midea’s Canadian sheet says the MAD50PS1QGRC pump can work “as high as 16,4 feet vertically.” LG’s UD501KOJ5 sheet lists “Internal Pump Yes” and “5m Hose Accessary Yes” (spelling as printed). Restoration units such as the AT250RS list an “Automatic Pump” that “Pumps captured water out of the unit through the drainage hose eliminating dump buckets.”
Before buying, note the distance and height to the nearest drain and compare them with the pump limits in the manual.
Check recall status before you rely on a unit
A borrowed, used or long-stored dehumidifier should be checked against federal recall notices. CPSC’s dehumidifier recall page lists several Gree actions. The November 29, 2016 reannouncement covered “About 2.5 million” units sold “from January 2005 through August 2013.” It names brands including “Danby, De’Longhi, Fedders, Fellini, Frigidaire, GE, Gree, Kenmore, Norpole, Premiere, Seabreeze, SoleusAir” and “SuperClima.” CPSC said: “The dehumidifier can overheat, smoke and catch fire, posing serious fire and burn hazards to consumers.”
A separate August 16, 2023 recall covered “About 1.56 million” dehumidifiers sold under the “brand names Kenmore, GE, SoleusAir, Norpole and Seabreeze” “starting in 2011 through 2014.” The remedy reads: “Consumers should immediately stop use, unplug the dehumidifiers, and contact Gree to receive a refund.” The 2023 notice says “The model number and date code are printed on a sticker on the back, front, or side of the unit.” The 2016 notice uses nearly the same wording.
CPSC’s 2023 warning reports “more than 2,000 reported incidents of these recalled dehumidifiers overheating” and “reports of four deaths potentially associated with Gree dehumidifiers.” It says “CPSC urges all consumers to inspect their dehumidifiers and take advantage of the recalls if they own affected products.”
Know the limits of this guide
This guide reads published documents. It does not measure how much water any unit removes in a real room, and no product was tested. A rating at 65 °F or 80 °F is a lab condition, and real rooms vary. The model examples are not a market survey, and some may be discontinued. The ENERGY STAR conversion table is approximate, and ENERGY STAR notes that actual changes vary by model. Federal rules, ENERGY STAR criteria and recall lists can change after November 16, 2026, so check the current versions before you buy.
Primary references checked November 16, 2026: Electronic Code of Federal Regulations, 10 CFR Part 430 Subpart B Appendix X1 (Uniform Test Method for Measuring the Energy Consumption of Dehumidifiers); U.S. Department of Energy, Federal Register final rules on dehumidifier test procedures (July 31, 2015 and July 26, 2023) and energy conservation standards (June 13, 2016); ENERGY STAR, Dehumidifiers; ENERGY STAR, Dehumidifier Testing and Capacity; ENERGY STAR, Dehumidifiers Key Product Criteria; LG, UD501KOJ5 Spec sheet and product page; Midea, CUBE MAD50PS1QGRC Specifications and MAD50PS1QWT product page; Frigidaire, Dehumidifier use and care manual 16120100A16032; Legend Brands, Dri-Eaz LGR 6500XLi Specifications; Abatement Technologies, AQUATRAP® AT250RS LGR Dehumidifier; U.S. Consumer Product Safety Commission, Dehumidifiers recall page, Gree reannouncement (November 29, 2016), Gree recall (August 16, 2023) and CPSC Warning (2023).
Frequently asked questions
Why does my old 70-pint dehumidifier seem to match a new 50-pint model?
The test changed. DOE moved portable dehumidifier testing from 80 °F to 65 °F, and ENERGY STAR says a unit tested to the new procedure will likely report a smaller capacity. ENERGY STAR’s approximate conversion table maps an old 70-pint rating to about 40 to 45 pints under the new test.
Is integrated energy factor the same as capacity?
No. Capacity is pints of water removed per day under the test conditions. Integrated energy factor is liters of water removed per kilowatt-hour of energy. ENERGY STAR says a higher integrated energy factor generally means a more efficient dehumidifier.
Can I compare a restoration dehumidifier’s AHAM pints with a home unit’s DOE pints?
Not directly. The Dri-Eaz LGR 6500XLi specifications state AHAM water removal at 80 °F and 60% RH, while DOE tests portable units at 65 °F and 60% RH. Saturation figures use even wetter, warmer conditions. Compare numbers only when the conditions match.
How do I know if a dehumidifier was recalled?
Check the brand and model number against CPSC recall notices. CPSC says the model number and date code on the recalled Gree units are printed on a sticker on the back, front or side of the unit. CPSC urges consumers to inspect their dehumidifiers and act on recalls if they own affected products.
Disclaimer: This guide is general information based on manufacturer, standards and government documents, not professional restoration, electrical or building-science advice for a specific building or product. Follow the manual and safety instructions for your model and check recall status before use. Rules and ratings may change. AI tools assisted with drafting. ClearTrade Report Editorial Team checked the cited sources and edited this guide.